32
Troubleshooting tools
Your ST70 pilot head has the following in-built user diagnostic functions:
• About Display
• About System
Use these as appropriate to help isolate problem areas.
About Display
The About Display function provides information about the pilot head on which it is
run. Before seeking technical assistance, please use the About Display function
whenever possible to find out the relevant:
• Software Version Number
• Hardware Version Number
• Bootloader Version Number
• Temperature
•Voltage
• Current
• Total hours run
To run the About Display function:
1. With the pilot head switched on, press
MENU
to
display the Main Menu, then use
<
or
>
to select
the
Diagnostics
option.
2. Press
ENTER
to display the
Diagnostics
menu.
3. Use
<
or
>
to select the
About Display
option,
then press
ENTER
.
4. The
About Display
information is displayed.
Make a note of the data you need then press
ENTER
:
• If you have seen all the available data the
display shows the
Diagnostics
menu.
• If there is more data to be displayed, the
next page of About Display data is dis-
played. Repeat step 4 until the display shows the
Diagnostics
menu.
About System
The About System function provides a list of products on the system and a serial
number for each product.
To run the About System function:
1. With the
Diagnostics
menu displayed, use
<
or
>
to select the
About System
option.
2. Press
ENTER
to display the
Diagnostics
menu.
D10095-1
Press ENTER to select.
Main Menu
Diagnostics
Press ENTER to continue.
About Display
D10939-1
Software Ver.
Hardware Ver.
Bootcode Ver.
Temperature
Volts
Peak Volts
Current
Peak Current
Run Time
V0.07
V0.21
V0.19
29.72 C
14.20 V
14.74 V
165 mA
221 mA
18.45