Raymarine E Series Guía de instalación Pagina 143

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 198
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 142
Chapter 6: Using the Fishfinder 6-21
How do I select a single frequency?
To display a single frequency in all fishfinder windows:
1. Press FISHFINDER SETTINGS.
2. Toggle FREQUENCY to MAN and FREQ MODE to SINGLE.
3. Toggle SELECTED FREQ to either 50 kHz or 200 kHz (default)The selected frequency
is applied to the scrolling bottom and indicated in the status bar.
4. Press OK or CANCEL twice to return to the default display.
Note:
Changing the frequency in a single fishfinder window will automatically change
all other fishfinder windows to that frequency.
Dual frequency mode
In dual frequency mode the DSM pings at the same rate but alternates between 200
kHz and 50 kHz. This allows you to select the required frequency(s) - 50kHz, 200 kHz or
BOTH for each individual fishfinder window. Combine this mode with the zoom,
bottom lock and A-scope functions to customize each fishfinder window to meet your
particular requirements or fishing conditions. For example, when you are in deeper
water you can set one fishfinder application to 200 kHz and another to 50kHz. Display
the 50 kHz in normal mode to show full bottom detail and a long history. This will give
you an overview of the current fishing conditions. Display the 200 kHz window in full-
pan zoom to view the top of the water column in very high detail and see fish
swimming near the surface. In a third fishfinder application, select BOTH to split the
window and display a high resolution image (200 kHz) and a wider cone (50kHz)
simultaneously. Using these settings covers all possibilities and ensures that nothing is
missed.
Note:
When BOTH is selected, any changes that you make to the zoom, bottom lock,
A-scope etc. will be applied to both images within that window.
How do I select duel frequency mode?
To select the frequency(s) for each fishfinder window:
1. With the required fishfinder window active, press FISHFINDER SETTINGS.
2. Toggle FREQUENCY to MAN and FREQ MODE to DUAL.
3. Toggle SELECTED FREQ to:
OR
D7352-1
FREQUENCY
FREQ MODE
SELECTED FREQ
FISHFINDER
SETTINGS...
SELECTED FREQ
200
50
IN
LE
MA
N
D7353-1
FREQUENCY
FREQ MODE
FISHFINDER
SETTINGS...
SELECTED FREQ
200 50 BOTH
D
U
AL
MA
N
81244_1.book Page 21 Wednesday, December 1, 2004 11:41 AM
Vista de pagina 142
1 2 ... 138 139 140 141 142 143 144 145 146 147 148 ... 197 198

Comentarios a estos manuales