SeaTalk
hs
patchcables
CablePartnumber
1.5m(4.9ft)SeaTalk
hs
patchcable
E06054
5m(16.4ft)SeaTalk
hs
patchcable
E06055
10m(32.8ft)SeaTalk
hs
patchcable
E06056
15m(49.2ft)SeaTalk
hs
patchcable
A62136
20m(65.6ft)SeaTalk
hs
patchcable
E06057
4.3Powerconnection
Powermustbesuppliedtothecamerafromanappropriatepower
source.
Powerconnectionrequirements
12or24Vdcnominalsupplyvoltage
Isolatedpowersupply
Connectedviaanappropriatelyratedthermalbreakerorfused
switch.
Powerconnectioncolors
ColorDescription
Red
Powerin+ve(12/24V)
Black
Powerin-ve(0V)
GreenDrain/Ground
Powercable
Thepowerconnectionismadetoa450mm(18in)tailoutofthe
camerabase.Extendthistailwithappropriatecableasperthetable
below.
Totallength(max)SupplyvoltageCablesize
12V
1.5mm
2
(16AWG)
0–8m(25ft)
24V
0.8mm
2
(18AWG)
12V
2.0mm
2
(14AWG) 8–16m(50ft)
24V
0.8mm
2
(18AWG)
12V
3.5mm
2
(12AWG) 16–24m(75ft)
24V
0.8mm
2
(18AWG)
12V
5.5mm
2
(10AWG) 24–32m(100ft)
24V
0.8mm
2
(18AWG)
Breakers,fusesandcircuitprotection
Raymarinerecommendsthatyoutathermalbreakerorfusefor
thecameraatthedistributionpanel.
CameraRecommendedfuse
Allmodels5Amp.
Sharingabreaker
Wheremorethan1pieceofequipmentsharesabreakeryoumust
provideprotectionfortheindividualcircuits.E.g.byconnectingan
in-linefuseforeachpowercircuit.
D11637-1
+VE bar
Circuit breaker
FuseFuse
-VE bar
Where possible, connect individual items of
equipment to individual circuit breakers.
Where this not possible, use individual in-line
fuses to provide the necessary protection.
Cablesandconnections
21